2012 Buildings Bulletins Legend: R if Rescinded |
Issuance
Date | Type/
Bulletin # | Relevant Code Sections | Purpose |
January 10, 2012 | OTCR /
Buildings Bulletin
2012-001 | AC 28-304
AC 28-113.2.3
BC 3001.9
1 RCNY 11-01
1 RCNY 101-07 | This document establishes acceptance criteria for buffers, interlocks, elevator entrances, wedge shackles, elevator governors, and elevator brakes in accordance with the 2008 NYC Construction Codes. |
January 10, 2012 | OTCR /
Buildings Bulletin
2012-002 | AC 28-103.9
AC 28-113.1
BC 1704.18
EC 500.5 | This document establishes acceptance criteria for site-specific approval of fuel gas compressors, duct burners and heat recovery steam generators used in cogeneration and Combined Heat and Power (“CHP”) projects. |
February 10, 2012 | Zoning /
Buildings Bulletin
2012-003 | ZR 12-10 (definition of “predominantly built-up area”) | This document clarifies the applicability of “predominantly built-up area” bulk regulations for existing residential buildings. |
March 26, 2012 | OTCR /
Buildings Bulletin
2012-004 | AC 28-113
BC 1704.6.3
BC 1704.13
BC Chapter 23
BC 2303
BC 2308.10.7.1
RCNY 101-06
BC Chapter 6
BC 714.2 | This bulletin establishes acceptance criteria for prefabricated parallel chord wood trusses in accordance with the 2008 NYC Construction Codes. |
April 6, 2012 | OTCR /
Buildings Bulletin
2012-005 Supersedes: OTCR/Buildings Bulletin 2010-026 Superseded by: OTCR/Buildings Bulletin 2013-004 | AC 28-113.2.3
FGC 303.3
FGC 503.4.2
FGC 503.8
FGC 601.3
FGC 503.2.2
PC 804.1 | This document establishes acceptance criteria for gas-fired direct vent space-heating appliances used for providing heat in rooms for sleeping purposes in accordance with the 2008 NYC Construction Codes. |
June 6, 2012 | OTCR /
Buildings Bulletin
2012-006 | AC 28-113.2.3
BC 1704.24
FGC 501.12
MC 801.16 | This document establishes additional acceptance criteria for relining systems installed in existing chimneys and vents. |
June 6, 2012 | OTCR /
Buildings Bulletin
2012-007 | AC 28-113.2.2
BC 1604.2
BC 1704.13 | This document establishes acceptance criteria for post-installed anchors in masonry in accordance with the 2008 NYC Construction Codes. |
June 29, 2012 | Zoning /
Buildings Bulletin
2012-008 | ZR 12-10 | This document clarifies the permitted size of a cellar that is accessory to a residential use and used for non-dwelling purposes. |
June 29, 2012 | Technical /
Buildings Bulletin
2012-009 | LL 5/73
LL 26/04 | This document clarifies temporary sprinkler installation and compartmentation requirements for existing buildings undergoing interior alterations. |
August 21, 2012 | OTCR /
Buildings Bulletin
2012-010 Superseded by: OTCR/Buildings Bulletin 2013-008 | AC 28-113.2.1
AC 28-113.2.2
MC 1301
MC 1302.3
MC 1305.9 | This document establishes acceptance criteria for flexible double wall fuel-oil pipe systems as alternative materials to the 2008 NYC Construction Code. |
October 19, 2012 | OTCR /
Buildings Bulletin
2012-011 Supersedes: OTCR/Buildings Bulletins 2009-028 and 2009-029 | AC 28-113
BC 1704.13 (Item 1)
BC 1704.25
BC 419.2
BC 712.3.1
BC 716
BC 909.3
BC 909.10.2
MC 607.2.1
MC 513.3
MC 513.10.2 | This document establishes acceptance criteria for fire resistive duct assemblies as approved alternative protection in the 2008 NYC Construction Codes. |